Varmra · Guide
Reviewing a building in 3D
Varmra draws an imported building as glass and lights inside it what the energy calculation counts, so you can check an import by looking at it.
What the review is for
When Varmra reads a building model, it works out the building's envelope: the heated floor area, every wall, roof, floor, window and door with its area and U-value, and the thermal bridges. The 3D review lets you see that envelope inside the building it came from, and answer the questions an energy calculation stands on:
- Is the heated floor area right? Atemp is lit storey by storey, inside the real walls. It is easy to see where it ends and what was left out.
- Are the windows right? A missing or doubled window, or one on the wrong facade, stands out.
- Where does the heat go? Every surface coloured by its U-value, or by its heat flow at a given hour.
- Are the thermal bridges where they should be? The junction lines are drawn exactly where Varmra measured them.
- What did Varmra assume? Anything the import had to guess carries a pin you can answer.
The view is on the Building envelope step, above the envelope table.
Which buildings get it
| How the building came in | What the view shows |
|---|---|
A building on EikHub (Import from EikHub, or the connector's import_from_eikhub) | The building as glass, with the envelope lit inside it |
A Stomra model through the connector (import_stomra) | The same |
An OpenEik folder (import_openeik) | The same |
| Geometry sent by an assistant, without a model | The envelope surfaces in the same look, with every lens; no glass building, since there is none to draw |
| Areas typed by hand | A schematic box: there is no geometry to review |
Varmra keeps the imported model with the project, so the glass building is drawn again each time the project opens. A project without its imported model shows the envelope only, with a note to import the building again.
The lenses
The building stays as glass in every lens. A lens chooses what is lit inside it. The legend sits under the view, so nothing covers the building, and the same colours appear in the envelope table.
Atemp
Each heated storey's floor glows red, labelled with its Atemp in m². The inside faces Varmra counts as Aom are faint red glass. Windows are crimson and doors wine red; they are shown under "Also lit, not part of Atemp", since Atemp is a floor area only. Rooms left out of Atemp, such as a garage or an unheated store, are drawn grey and hatched with their name and area, so you can see why Atemp is smaller than the floor. If the Atemp typed on the Project step differs from the model's by more than 0.5 %, the legend says so.
U-value
Each surface is coloured by its U-value on one scale for every part, logarithmic from 0.1 to 2.5 W/(m²·K), green to red. The same colour always means the same U. The colour comes from the calculation's own row, so changing a U in the table recolours the surface at once.
Thermal bridges
The envelope turns to faint glass and each junction is drawn as a glowing line in its ψ's colour, pale amber at 0.02 to red from 0.2 W/(m·K): wall to slab, wall to roof, intermediate floors, around windows and doors, and the corners. The lines are where Varmra measured the junctions, so their lengths are the lengths the calculation uses. The legend lists ψ, length and ψ·L per junction, with Σψ·L and its share of the transmission loss. When the calculation uses a percentage allowance for thermal bridges instead, the legend says so.
Heat flow
One hour of the year at a time, from the hourly calculation. Every element of the envelope is drawn solid, as a thermal camera sees it from outside: red where it gives off heat, blue where it takes heat in, pale where little passes. A window takes off the sun it lets in.
- Choose the hour with the Day of the year and Hour sliders, or press play to step through the hours.
- The real sun stands in the sky where it is at that hour.
- The legend shows the inside and outside temperatures, the heating against the year's peak, two bars for what comes in (heating, sun, people and appliances) and what goes out (transmission, ventilation, leaks, the building's mass), and transmission by kind of part.
On a sunny winter noon the walls are red and the south windows blue. At night everything is red. In July nearly everything is pale.
Zones
Shown when the project has zones. Each envelope part is drawn in its zone's colour, and each zone is labelled with its air temperature at the hour the heat flow lens shows. Unheated zones are grey, at the temperature they float to. With zones, the heat flow lens reads each part against its own zone's air: a crawl space's walls lose heat at the crawl space's temperature, not the flats'. See Zones in an energy balance.
The picture and the table are one
Every lit surface knows its row in the envelope table.
- Click a surface (or a junction line): a small popup names it with its area, U and U·A (its heat at that hour in the heat flow lens; ψ and ψ·L for a thermal bridge). Show in the table scrolls to its row and marks it.
- Point at a row in the table: its surfaces come into focus in 3D, and everything else turns to faint glass of its own colour.
- Each U and ψ in the table carries a swatch of its colour on the lens's scale.
Checks and assumptions
Where the import had to assume something (a default U where the model gives no thermal data, a λ taken from a material's name, a roof window with no type), an amber pin sits on the part it concerns, in every lens. Things to look at, such as a window that does not lie in its wall's face, get a pin too.
- Open a pin. It gives the reason and lights the parts it concerns.
- Answer it. Looks right turns the pin into a green tick. Needs fixing keeps it amber, ringed red, with your note. Each answer records who gave it and when, and can be undone.
- Accept the assumptions. In the legend, one by one or with Accept all. Typing your own U-value in the table also settles the assumption for that part.
- Follow the count. The legend counts down what is left ("2 of 3 to check") and stays amber while anything is open or needs fixing.
Answers are saved with the project and kept over a new import when the item comes back unchanged. A connected assistant can read the answers but cannot give them on your behalf.
Looking inside
3D or Plan
Plan looks straight down with north up: the clearest way to check an Atemp outline against the walls. The view still turns from there.
One storey
Pick a storey and everything above its ceiling is cut away, with its labels.
A section
Section north–south or east–west, with a slider for where it cuts.
Day or Night
A light or a dark backdrop. The view remembers your choice in this browser.
A north arrow shows the model's true north, which is also what the windows' solar gains are calculated with.
In the report
The printed report's building envelope chapter gets three pictures from the review: Atemp from above, Atemp from the south-east, and the U-values from the south-east with the scale under it, captioned in the report's language. They are drawn while the report is open and redrawn when the envelope or a U-value changes. The same chapter carries Review of the model: each check and assumption with its answer, who gave it and when, or "Open".
Example: the L-house
OpenEik's example building, the L-house, is a study model with uninsulated walls, which makes the lenses easy to read:
| Atemp | 103.2 m² |
|---|---|
| ΣU·A | 305.1 W/K, of which the walls 251.6 W/K; Um 0.871 |
| Main roof | 38.43 m², U 0.194, U·A 7.5 W/K (point at it to read this) |
| Thermal bridges | four junction rows, Σψ·L 12.2 W/K, 3.8 % of the transmission loss; the roof junction ψ 0.060 over 49.9 m |
| Check | one pin: the roof window has no type, so it got the default U of 1.1 |
In the heat flow lens in Stockholm on 28 February at 11:00, the heating gives 5.29 kW, 69 % of the year's peak; 6.17 kW leaves by transmission, 4.96 kW of it through the walls, and the south window shows blue as it takes in the sun.